After replacing the battery (this method can also be used to confirm whether other faults are causing abnormal starting before replacing the battery), if the normal start state is still not achieved, we can analyze the fault by examining the peak value of the starting current

After replacing the battery (this method can also be used to confirm whether other faults are causing abnormal starting before replacing the battery), if the normal start state is still not achieved, we can analyze the fault by examining the peak value of the starting current. The clamp ammeter should be clamped onto the thick positive terminal line of the battery (the general battery's positive terminal has two lines, one for the starting device and one for power supply). Set the clamp ammeter to DC current and enter peak measurement mode. Start the engine, read and compare the peak value displayed on the clamp meter with that specified by car manufacturers (as different motor models have different starting currents). 

If it is lower than normal, please check in this order: battery positive cable contact, starting switch SW, switch conduction spring, battery negative cable; pay special attention to potential poor contacts in these areas. First set your clamp ammeter function switch to DCA file. Clamp it onto a wire from alternator to battery while paying attention to aligning its arrow direction with that of current flow direction indicated on meter head. Start engine and observe LCD display showing charging current; after normal operation starts, this value will gradually decline which indicates normal functioning. To determine whether alternator is functioning properly: duty cycle refers to percentage of positive half cycle within a pulse signal during each complete cycle. In engine electronic control system testing, various electromagnetic valves operate using pulse currents such as electronic carburetor mixed ratio control solenoid valve, idle solenoid valve, EGR solenoid valve, activated carbon tank control valve and distributor hall sensor detection. By comparing measured duty cycle values with standard values provided by automobile manufacturers respectively for each component mentioned above,it becomes easy to determine their operational status.

Click:
Like | 0
share
The application of clamp meter in automobile diagnosis
After replacing the battery (this method can also be used to confirm whether other faults are causing abnormal starting before replacing the battery), if the normal start state is still not achieved, we can analyze the fault by examining the peak value of the starting current
Long by picture save/share

SEND AN INQUIRY

Fill out the form below to contact us

  • Your Name *

  • Tel *

  • E-mail *

  • Message

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

REQUEST A

QUOTE TODAY

 

Whether is a product enquiry or technical help
please send messager here,
our team will respond within 24-48 hours.

图片展示

+86 0752-2608993

4F and 5F, No.5 Building, Yinghui Technology Park, No.6Dongsheng North Road,Chenjiang Sub-district, ZhongKaiHi-techDistrict, Huizhou City,Guangdong Province, China

Copyright © Huizhou Fu Yi Electronic Technology Co., Ltd.

 

Technical Support: Yueshang Technology

图片展示

+86 0752-2608993

4F and 5F, No.5 Building, Yinghui Technology Park, No.6Dongsheng North Road,Chenjiang Sub-district, ZhongKaiHi-techDistrict, Huizhou City,Guangdong Province, China

Copyright © Huizhou Fu Yi Electronic Technology Co., Ltd.  

 

Technical Support: Yueshang Technology

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了